Introduction to Ex Equipment Markings
Equipment markings are the "DNA" of hazardous location equipment - they tell you everything you need to know about where and how the equipment can be safely used. Understanding these markings is crucial for proper equipment selection, installation, and maintenance in explosive atmospheres.
Whether you're working with ATEX, IECEx, or North American certified equipment, the marking system provides critical safety information that ensures compliance and prevents dangerous misapplications.
Anatomy of IECEx/ATEX Markings
Let's decode a typical IECEx/ATEX equipment marking step by step:
Protection Methods (Ex Codes)
Intrinsic Safety
Energy limitation prevents ignition. 'ia' for Zone 0, 'ib' for Zone 1.
Flameproof
Explosion contained within enclosure, prevents propagation to surrounding atmosphere.
Increased Safety
Enhanced construction prevents ignition sources under normal and specified fault conditions.
Non-Sparking
Equipment not capable of igniting explosive atmosphere under normal operation.
Encapsulation
Ignition sources enclosed in compound to prevent ignition of explosive atmosphere.
Powder Filling
Enclosure filled with powder to prevent ignition propagation.
Gas Groups and Temperature Classes
Gas Group | Typical Gases | MESG (mm) | Ignition Current Ratio |
---|---|---|---|
IIA | Propane, Butane, Methane | ≥ 0.9 | ≥ 0.8 |
IIB | Ethylene, Dimethyl Ether | 0.5 - 0.9 | 0.45 - 0.8 |
IIC | Hydrogen, Acetylene | < 0.5 | < 0.45 |
Temperature Class | Maximum Surface Temperature | Example Substances |
---|---|---|
T1 | 450°C | Hydrogen, Methane |
T2 | 300°C | Ethanol, Gasoline |
T3 | 200°C | Kerosene, Diesel |
T4 | 135°C | Acetaldehyde, Diethyl Ether |
T5 | 100°C | Carbon Disulfide |
T6 | 85°C | Carbon Disulfide (special conditions) |
North American Markings
North American equipment follows different marking conventions based on Class/Division system:
North American Gas Groups
- Group A: Acetylene
- Group B: Hydrogen, manufactured gas
- Group C: Ethylene, cyclopropane
- Group D: Propane, gasoline, natural gas, butane
Critical Safety Note
Equipment marked for a higher gas group can be used in lower gas group applications (e.g., IIC equipment can be used for IIA applications), but NEVER the reverse. Similarly, equipment with a lower temperature class can be used where higher temperature classes are specified.
Equipment Protection Levels (EPL)
Modern IECEx/ATEX markings include Equipment Protection Levels that indicate the level of protection:
Gas Equipment Protection Levels
- Ga: Very high protection (Zone 0 suitable)
- Gb: High protection (Zone 1 suitable)
- Gc: Enhanced protection (Zone 2 suitable)
Dust Equipment Protection Levels
- Da: Very high protection (Zone 20 suitable)
- Db: High protection (Zone 21 suitable)
- Dc: Enhanced protection (Zone 22 suitable)
Complete Marking Examples
Translation: Flameproof and increased safety combination, Gas Group IIC, Temperature Class T4, suitable for Zone 1 (Gb)
Translation: Protection by enclosure for combustible dust, suitable for Zone 20 (Da), maximum surface temperature 135°C, IP6X dust ingress protection
⚠️ Common Mistakes to Avoid
- Installing IIA equipment in IIC environments
- Using T6 equipment where T4 is required
- Mixing North American and International standards
- Ignoring ambient temperature effects on T-class
- Not considering dust and gas combinations
Special Marking Considerations
Ambient Temperature Effects
Equipment temperature class assumes standard ambient conditions. For installations in extreme temperatures, the actual surface temperature must be calculated considering the ambient temperature effect.
Multiple Protection Methods
Some equipment combines multiple protection methods, such as "Ex db eb" (flameproof terminals with increased safety motor). Each part of the equipment must meet its respective protection requirements.
Dust and Gas Combinations
In areas where both combustible dust and flammable gases may be present, equipment must be suitable for both hazards, requiring markings like "Ex db IIC T4 Gb Ex ta IIIC T135°C Da".
Best Practices for Equipment Selection
- Always verify compatibility: Ensure equipment markings match or exceed area classification requirements
- Consider future changes: Select equipment with higher protection levels if process changes are anticipated
- Check certification bodies: Ensure certifications are recognized in your jurisdiction
- Maintain documentation: Keep certification certificates and installation records
- Regular inspections: Verify markings remain legible and equipment condition is maintained
Conclusion
Understanding Ex equipment markings is fundamental to safe operation in hazardous locations. These markings provide critical information about protection methods, suitable environments, and operational limitations. Whether working with ATEX, IECEx, or North American standards, proper interpretation of equipment markings ensures both safety and regulatory compliance.
Remember: when in doubt, consult with qualified hazardous location engineers or certification bodies. The consequences of incorrect equipment selection in explosive atmospheres can be catastrophic.