EMC program management
Pass EMC the first time
Emissions and immunity strategy across residential, commercial, and industrial environments — before you burn expensive chamber days.

What this engagement covers
We classify your product’s electromagnetic environment, pick the right emission/immunity standards, run a pre-compliance plan, manage accredited testing, and drive design fixes (filtering, grounding, cable routing, shielding) until reports close.
Best fit for
- Switch-mode power, motor drives, and high-speed digital designs
- Products failing radiated or conducted emissions at first lab attempt
- Industrial equipment needing EN 61000-6-x / IEC 61326 paths
- Multimedia / IT gear targeting EN 55032/35 or FCC 15B
What's included
- Environment classification (residential vs industrial vs special)
- Emission + immunity test matrix with pass/fail criteria
- Schematic / enclosure / cable EMC risk review
- Pre-compliance scan plan and chamber booking strategy
- Failure root-cause support and remediation guidance
- Report package aligned to CE, FCC, or ISED filings
Product types we support
Scope changes by product architecture — these are the classes we regularly take through this pathway.
IoT gateways & hubs
Ethernet + Wi-Fi/BLE hosts with SMPS noise sources
Industrial HMI / PLC / drives
Cabinet-mounted controls, VFDs, servo drives
Medical electronics (EMC portion)
IEC 60601-1-2 immunity/emission overlays
Power converters & chargers
AC/DC, DC/DC, USB-C PD, EVSE peripherals
Automotive aftermarket electronics
CISPR 25 / ISO 11452 style programs when in scope
Lighting & LED drivers
Conducted/radiated emissions for luminaires
Technical categories
Typical test types
Regions & schemes
Market access is scheme-specific. We map filings and evidence to the regions you actually sell into.
EU / UK
- •EMC Directive / UK EMC
- •EN 55032/35
- •EN 61000-6-1/2/3/4
- •Harmonics/flicker EN 61000-3-2/3
United States
- •FCC Part 15B (unintentional)
- •Part 18 (ISM) when applicable
- •Supplier’s Declaration of Conformity
Canada
- •ICES-003
- •ICES-Gen
Australia / NZ
- •ACMA EMC
- •RCM pathway
Japan / Korea / others
- •VCCI (as applicable)
- •KC EMC
- •case-by-case mapping
Directives & regulations
2014/30/EU — EMC Directive
Essential requirements for apparatus and fixed installations
UK Electromagnetic Compatibility Regulations
UKCA equivalent path
FCC 47 CFR Part 15
Unintentional radiators (Class A / Class B)
Key standards
| Standard | Focus |
|---|---|
| EN 55032 / CISPR 32 | Multimedia equipment — emissions |
| EN 55035 / CISPR 35 | Multimedia equipment — immunity |
| EN IEC 61000-6-1 / 6-2 | Generic immunity — residential / industrial |
| EN IEC 61000-6-3 / 6-4 | Generic emissions — residential / industrial |
| EN 61326-1 | Electrical equipment for measurement, control and laboratory use — EMC |
| IEC 60601-1-2 | Medical electrical equipment — EMC (when medical) |
| EN 61000-3-2 / 3-3 | Harmonics and voltage fluctuations / flicker |
Marks & program keywords
How we work
One clear path from classification to market-ready evidence.
Classify
Product category and EM environment
Pre-scan
Risk-based checks before formal booking
Test
Accredited emissions & immunity campaign
Close
Fixes verified; reports ready for DoC / FCC
Engineering notes
Class A vs Class B limits and installation environment drive both design and labeling — we lock this early so marketing claims match the test plan.
We coordinate intentional-radiator (radio) EMC with unintentional apparatus EMC so RED/FCC radio work does not collide with 15B / EN 55032 campaigns.
Right standard set, not over-testing
Documented failure fixes
Reports usable across markets
Ready to scope EMC?
30-minute consultation with Hazloc Labs — bring your product type, target markets, and any existing reports.
Book Free CallRelated services

CE Marking & UKCA
Directives, harmonized standards, testing coordination, and technical documentation — handled end to end for EU and UK market access.

RF & Wireless Certification
FCC, RED, ISED, MIC, ACMA, and multi-country radio paths for modules, hosts, and custom radios — including antenna and SAR considerations.

Product Safety (UL / CSA / IEC)
UL, CSA, IECEE CB Scheme, and IEC/EN safety standards — construction review, critical components, and NRTL project management.